Purpose:

Conventional fire alarm systems are designed to detect a fire at an early stage and warn building occupants of the danger. They provide a fast response through audible and visual signals, helping to effectively evacuate people and reduce the risk of serious damage. Their main purpose is to localize the location of the fire in certain areas, which allows for rapid action to be taken to extinguish or limit the spread of the fire.

 

Application area:

The alarms can be used in any indoor space or building.

Certified to EN54-7 by Intertek (0359-CPR-00183).
Sensitivity: nominal alarm threshold of 0.16 db/m smoke measured in accordance with EN54-7:2000.
2-wire polarity sensitive trace wire.
Supply/operating voltage from 9 to 33V DC.
Static current: 30 µA at 24 VDC.
Alarm voltage 6-33V DC.
Product dimensions (mm) 102.2mm diameter x 37mm depth (detector at base); 102.2mm diameter x 57.5mm depth.
Construction: white polycarbonate housing with UL94 V-2 rating with nylon parts.
Weight: 99 grams

Price : €23 - 45lv

ActiV C4416
897b61f8aef5496a3828d824ff4ba94fa91aa0eb_edited.png
image.png

€23 - 45лв

Certified to EN54-5 by Intertek (0359-CPR-00183).
Creates an alarm condition when it detects a temperature between 54ºC and 65ºC.
2-wire polarity sensitive trace wire.
Supply/operating voltage from 9 to 33V DC.
Static current: 30 µA at 24 VDC.
Alarm voltage 6-33V DC.
Product dimensions (mm) 102.2mm diameter x 37mm depth (detector at base); 102.2mm diameter x 57.5mm depth.
Construction: white polycarbonate housing with UL94 V-2 rating with nylon parts.
Weight: 99 grams
Price: €19 - 38lv

ActiV C4403A2
image_edited.png
image.png

€19 - 38лв

Certified to EN54-5 by Intertek (0359-CPR-00183).
Creates an alarm condition when it detects a temperature between 69ºC and 85ºC.
2-wire polarity sensitive trace wire.
Supply/operating voltage from 9 to 33V DC.
Static current: 30 µA at 24 VDC.
Alarm voltage: 6-33V DC
Product dimensions (mm) 102.2mm diameter x 37mm depth (detector at base); 102.2mm diameter x 57.5mm depth.
Construction: white polycarbonate housing with UL94 V-2 rating with nylon parts.
Weight: 99 grams
Price €19 - 38lv

ActiV C4403B
image_edited.png
image.png

€19 - 38лв

Certified to EN54-5 by Intertek (0359-CPR-00183).
It creates an alarm condition when it detects a sudden increase in temperature or if it detects a static temperature between 54ºC and 65ºC.
2-wire polarity sensitive trace wire.
Supply/operating voltage from 9 to 33V DC.
Static current: 30 µA at 24 VDC.
Alarm voltage 6-33V DC.
Product dimensions (mm) 102.2mm diameter x 37mm depth (detector at base); 102.2mm diameter x 57.5mm depth.
Construction: white polycarbonate housing with UL94 V-2 rating with nylon parts.
Weight: 99 grams
Price: €21 - 42lv

ActiV C4403A1R
image_edited.png
image.png

€21 - 42лв

Certified to EN54-5 and 7 by Intertek (0359-CPR-00183).
Operates independently and the C4414's smoke and heat sensors combine to create a sensitive response to free-burning fires
2-wire polarity sensitive trace wire.
Supply/operating voltage from 6 to 33V DC.
Static current: 30 µA at 24 VDC.
Alarm voltage 6-33V DC.
Product dimensions (mm) 102.2mm diameter x 37mm depth (detector at base); 102.2mm diameter x 57.5mm depth.
Construction: white polycarbonate housing with UL94 V-2 rating with nylon parts.
Weight: 99 grams

Price: €33 - 65lv

ActiV CC4414
eacf1ed51717d39ccca5e1bd8b351fe4388598bc
image.png

€33 - 65лв

Certified to EN54, part 11 (LPCB / VdS).
Includes:
470Ω resistor
Test key
Red back box.

Price: €28 - 55lv